-
GDYD-53D 50kV AC DC Dielectric Test Equipment
AC hi-pot testing is the effective and direct way to test insulation strength for electrical equipment, apparatus, or machines. It checks dangerous flaws which assure electrical equipment continuous working.
-
GDFR-C1 Series AC/DC High Voltage Divider
GDFR-C1 series AC/DC digital meter is on-site instrument, which test both AC and DC voltage. It consists of voltage divider and measurement instrument.
-
GD9850A Portable AC/DC Insulation Tester for Industrial Applications
The AC DC Insulation Tester is electric safety device. It is neat and compact structure with mature technology. It is widely used for household appliance, instrument, and components etc.
-
GDYD-2030A 30kVA.200kV Automatic AC/DC Hipot Test Set
GDYD-2030A Automatic AC/DC Hipot Test Set is composed of automatic control unit and gas testing transformer (HV unit) which output AC or DC voltage smoothly. Meanwhile, it has many monitoring and protection functions.
-
GDYD-53A Automatic AC/DC Hipot Test Set
AC/DC Hipot testing is the effective and direct way to test insulation strength for electrical equipments,apparatus or machines. It checks dangerous flaws which assure electrical equipment continuous working.
-
GDFR-D1 AC/DC High Voltage Divider
GDFR-D1 Series AC/DC digital meter is on-site instrument, which test both AC and DC voltage. The digital meter and divider are equipped in one unit.
-
GDVLF-80S High Voltage VLF AC Hipot Test Set for Cable Insulation Testing
Withstand voltage test is an essential preventive test for electrical equipment. It is divided into two parts: AC and DC withstand voltage test. AC test can be further divided into power frequency, variable frequency and 0.1Hz very low frequency test, among which the last one is highly recommended by IEC, due to its remarkable advantages.
-
AC High Voltage Test Sets for GIS
AC Resonant Test System for Substation Electrical Equipment, is mainly composed of variable frequency power supply, Excitation Transformers, Reactors, Capacitive dividers, which designed for AC withstand voltage test of substation electric equipment at 500kV or below.
-
GDZJ-5S Surge Generator For Motor
GDZJ-5S is used to test turn-to-turn insulation strength of single-phase motor, 3-phase motor, Micro motor, Special motor, electrical motor, transformer (including switching mode power supply transformer), relay and winding electrical equipment.
-
GDYD-63A Versatile AC/DC Hipot Test Set for Comprehensive Electrical Testing
GDYD-63A AC/DC Hipot Test Set is composed of automatic control unit and AC oil testing transformer (HV unit) which output AC voltage smoothly. Meanwhile, it has many monitoring and protection functions. When the short circuit rod of testing transformer is taken out, the output is DC voltage.
-
GDTF Variable Frequency AC Resonant Test System
GDTF Series AC Resonant Test System For Cables are composed of frequency/voltage adjustment power supply, excitation transformer, reactors and capacitive divider.The power frequency can be adjustable, which make the reactor and tested capacitor resonance.
-
GDZJ-10S Turn-to-turn Surge Tester
GDZJ-10S is used to test turn-to-turn insulation strength of single phase motor, 3-phase motor, Micro motor, Special motor, electrical motor, transformer (including switching mode power supply transformer), relay and winding electrical equipment.